Heating Repair for NYC Buildings
Heat That Reaches Every Room
Cold radiators, banging pipes, and uneven heat usually point to the distribution system, not just the boiler. We check the boiler and the piping together so heat reaches every room.
We repair one-pipe and two-pipe steam systems and hot water systems in homes and multifamily buildings.
In an apartment building, a cold apartment is rarely a problem with that apartment alone. Steam and hot water travel up shared risers from the boiler room, so a failed main vent, a clogged return, or a sagging pipe in the cellar can leave a whole line of apartments without heat. We trace the problem back through the riser and the mains before replacing parts, which keeps the repair targeted and the cost down.
NYC's heat season runs October 1 through May 31, and building owners are responsible for keeping heat at the required levels the whole time. Fixing distribution problems before the first cold snap is usually faster and cheaper than chasing them in January.
Signs You Need Service
- Radiators that stay cold or heat unevenly
- Banging or hammering when the heat comes on
- Upper floors or far rooms that never warm up
- Leaks at radiators, valves, or pipes
- A boiler that short-cycles or runs constantly
Two Systems, Different Fixes
Knowing which system you have points straight to the likely problem.
Steam: problems usually come from air vents, steam traps, pipe pitch, or the boiler's water level.
Hot water: problems usually come from trapped air, circulator pumps, zone valves, or controls.
One-pipe steam: each radiator has a single pipe and an air vent. A vent that sticks shut leaves the radiator cold, and one that sticks open hisses or spits water.
Two-pipe steam: each radiator has a supply and a return, with a steam trap on the return. A failed trap lets steam into the returns, which causes banging and uneven heat across the building.
We fix the cause, not just the symptom, and explain what we found.
Get your heat working rightHeating Problems We Fix
- Cold radiators. Failed vents, traps, valves, and air-bound piping.
- Banging & hammering pipes. Trapped water from poor pitch or failed steam traps.
- Uneven heat. Balancing systems so upper and far rooms get heat too.
- Circulators & zone valves. Pump and zone valve repairs for cold zones.
- Controls & thermostats. Controls and sensors that cause short-cycling or no heat.
- Leaks. Leaking radiators, valves, and heating pipes.
How We Approach Heating Repairs
A methodical process that finds the real problem in the boiler or the pipes.
Listen
Where it's cold, when it happens, and what you hear tell us a lot.
Inspect
We check the boiler and the distribution system together.
Repair
We fix the cause and explain what we did.
Verify
We run the system and confirm heat reaches the problem areas.
Heating Repairs That Last
Older NYC heating systems need someone who understands steam and hot water, not just boilers.
Steam & Hydronic Know-How
Repairs for one-pipe steam, two-pipe steam, and hot water systems.
Since 2005
Our team has worked on NYC heating systems since 2005.
24/7 Emergency Service
If you have no heat, help is available any time.
Root-Cause Repairs
We find why it failed so the same problem doesn't come back.
Common causes are failed air vents or steam traps, closed or stuck valves, air in a hot water system, or piping that isn't pitched correctly.
In steam systems, banging (water hammer) usually means water is trapped in the piping because of poor pitch, failed traps, or an overfilled boiler.
Yes. We repair one-pipe and two-pipe steam systems and hot water (hydronic) systems.
Yes. If you have no heat, emergency service is available 24/7.
Short-cycling usually comes from an oversized boiler, a pressure control set too tight on a steam system, a faulty thermostat or sensor, or a low-water condition. It wastes fuel and wears out the burner, so it's worth fixing even when the heat still works.
A boiler with a sound heat exchanger can often run for years after a repair. If the heat exchanger or sections are cracked, or repairs keep coming back, a replacement is usually the better spend. We tell you which one applies after we inspect it.
Yes. On steam systems we replace main and radiator vents, repair traps, and correct pipe pitch. On hot water systems we purge air and adjust or repair circulators and zone valves so upper floors and far apartments heat evenly.